title: The Moment a Dry Puck Gets Wet
url: https://oosioo.com/en/p/%EB%A7%88%EB%A5%B8-%ED%8D%BD%EC%9D%B4-%EC%A0%96%EB%8A%94-%EC%88%9C%EA%B0%84
date: 2026-11-19T13:34:43+00:00
author: SYSOP
summary: I rebuilt the model Foster et al. (2025) fitted to CT images of a puck wetting, one per second. It reproduces the 6.67 s to full wetting, and what changes that time most is the air trapped above the puck (4.5–11.2 s for a 3–20 mm headspace). Splitting the puck into 30×30 columns of uneven permeability, only 39% of it was wet when the first path opened, and pre-infusion did not change that share. Includes a puck wetting tool.
---
# The Moment a Dry Puck Gets Wet

Every puck calculation so far has assumed the puck is already soaked through. A real shot starts from dry grounds. When the pump starts, water pours onto the puck, wets it from the top down, and only when it reaches the bottom does the first drop fall. What happens in those few seconds?

In 2025 a study filmed this process with X-ray CT, one 3D image per second. I rebuilt their model and ran it. What changed the time to wet the whole puck most was the air trapped above it. When the puck's permeability varied from place to place, wetting times spread widely. And within this model, pre-infusion did not make the wetting front more even.

## Wetting, imaged every second

![An espresso machine seen from below. Brown streams of espresso fall from two bottomless portafilters (one a mirror reflection) into white cups](/uploads/f17848777a30e48a.webp =600)
*Espresso from a bottomless portafilter, with coffee coming straight off the bottom of the puck* · Photo: massage-techniques, Wikimedia Commons, CC BY-SA 2.0

Foster and colleagues (2025) modified a home espresso machine (a De'Longhi Dedica) and placed it inside a CT system whose X-ray source and detector circle the machine once a second. They tamped 10 g of coffee to 12 kg on a scale and took 30 3D images over 30 s. Where brightness changed from the dry state, water had entered.

With a fine grind, almost no water entered for the first 2 s, clear intrusion began around 4 s, and the whole puck was wet by about 7 s. The boundary between wet and dry was sharp and nearly flat. A coarse grind wetted faster but unevenly, with the walls wetting first.

They built a model of the process in three parts:

- **The pump** sends less water as pressure rises: none at its maximum of 15 bar, 317 mL per minute at atmospheric pressure
- **The air above the puck** in the headspace between shower screen and puck is trapped once water pools on the puck. Hot water heats it, and as water fills the space it is compressed and its pressure rises
- **The puck**: water flows through the wet part by Darcy's law, and the wetting front moves down at that rate

Fitting the model to the measurements gave a permeability of 2.97×10⁻¹⁵ m², a porosity of 0.322, and 6.67 s to wet the whole puck.

## Rebuilding the model

I rebuilt the model with the same equations and values. Water began pooling on the puck at 0.823 s and the puck was fully wet at 6.67 s, just as in the paper.

![Three charts with time (0–10 s) across. On the left, 'Wetting front': depth grows quickly at first, a little more slowly at 2–4 s, then quickly again, reaching the bottom (about 10 mm) at 6.67 s. In the middle, 'Pressure above the puck': rising slowly from 0, then steeply between 4 and 7 s, levelling off near 10 bar. On the right, 'Flow': water from the pump (grey) declines gradually from 5.2 to 2.7 mL/s, while water entering the puck (blue) drops from 5.2 to about 1 mL/s within the first second, then rises again to meet the pump at 2.7 mL/s](/uploads/887a8ee37ac7bd87.webp =760)

For a moment at the start, everything the pump sends goes straight into the puck, because the wet layer is still thin and the water path short. As the wet layer thickens, the puck takes in less than the pump delivers, and the excess pools on top. From then on, flow into the puck drops to a fifth (5.2 → 1.0 mL/s) in a little over a second. As Foster and colleagues pointed out, this happens without any extraction, CO₂ or swelling in the model. The water pooling on top then compresses the air, pressure rises, and flow speeds up again. So the wetting front speeds up, slows down and speeds up again.

## What sets the time to wet

I changed one thing at a time.

![Two charts. On the left, 'Changing one at a time': horizontal bars show the range of times to fully wet. Permeability ×1/4 to ×4: 5.0–9.8 s; headspace 3–20 mm: 4.5–11.2 s; pump maximum pressure 6–15 bar: 6.7–7.8 s; porosity 0.2–0.6: 5.6–8.8 s. The baseline 6.67 s is dashed. On the right, 'Pre-infusion': capping the pump at 2 bar for the first 3, 6 or 10 s slows the wetting front and delays full wetting from 6.7 s to 8.9, 11.3 and 14.4 s](/uploads/bccceaea18855dbe.webp =760)

The biggest effect came from the headspace, the height of the empty space above the puck: 4.5 s with 3 mm, 11.2 s with 20 mm, more than a twofold difference. The more air is trapped, the longer it takes to compress it and raise the pressure. That means a smaller dose, which leaves more room above the puck, takes longer to wet. Changing permeability from a quarter to four times the baseline moved the time from 9.8 to 5.0 s. The pump's maximum pressure, between 6 and 15 bar, changed it by only a second or so.

I also added pre-infusion. Capping the pump at 2 bar for the first few seconds makes the front move slowly during that time, delaying full wetting by about as much: 8.9 s with a 3 s cap, 14.4 s with a 10 s cap.

## An uneven puck

Foster's model assumes the whole puck wets uniformly. A real puck's permeability varies from place to place. In the calculations of Mo and colleagues (2023), introduced in "Looking Inside the Puck with CT", six 0.7 mm cubes cut from the same capsule differed in permeability by up to fourteen times.

So I divided the puck's cross-section into 30×30 columns and gave each column a permeability drawn from a lognormal distribution. All columns share the pressure above the puck. I varied the spread of permeability (log standard deviation σ) at 0.3, 0.6 and 1.0 and recorded when each column wetted through to the bottom.

![Two charts. On the left, the wetting map at the moment the first column wets through (3.8 s) with σ 0.6: 30×30 cells range from pale yellow (shallow) to dark brown (deep), with only a few wet to the bottom. On the right, times for 900 columns to wet through (log axis): σ 0.3 first 5.1, median 6.7, last 9.7 s; σ 0.6: 3.8, 7.0 and 19.5 s; σ 1.0: 2.5, 7.6 and 39.7 s. The larger the spread, the further apart the first and last](/uploads/7b063598fea86608.webp =760)

With σ 0.6, the fastest column wet through at 3.8 s and the slowest took 19.5 s. When the first column broke through, 39% of the puck's volume was wet. So when water starts to rush down the first open path, more than half the puck is still dry. With σ 1.0 the first column took 2.5 s and the last nearly 40 s.

Then I added pre-infusion again. Capping pressure at 2 bar for the first 4 or 10 s left the wet volume at first breakthrough at 39%, unchanged. As long as all columns feel the same pressure, how deep each one is wetted relative to the others depends only on their permeability ratios, not on when or how pressure is applied. Within this model, pre-infusion only delays wetting; it does not even out the front.

That does not make pre-infusion useless. Some things are missing from this model. If wet particles swell and narrow the paths that wetted first, if CO₂ escapes at low pressure, or if water spreads sideways between columns, the result could differ. I found no peer-reviewed study that measured the effect of pre-infusion on extraction or channeling under controlled conditions.

## Carbon dioxide

A big omission in this model is carbon dioxide. Roasted coffee holds CO₂. According to Smrke and colleagues (2018), grinding freshly roasted coffee releases up to 75% of the trapped gas within 90 s. Still, finely ground coffee is reported to retain about 4–12 mg per gram. That is 2–7 mL per gram at room temperature, or 40–130 mL for 18 g (an estimate), far more than the empty space in the puck (about 9 mL for a 10 g puck). If water pushes this gas out or traps it as it soaks in, it could change the speed and shape of wetting.

## Wet it yourself

In the tool below, change permeability, headspace, pump maximum pressure, pre-infusion and how uneven permeability is, and watch 20×20 columns of the puck's cross-section wet over time. The table gives the time for the first column to break through, the wet share at that moment, and the time for all columns to wet through.

```map /embed/coffee-wetting-2026-en.html 16:9
Puck wetting tool. Sliders on the right set permeability (0.5–15×10⁻¹⁵ m²), headspace (2–20 mm), pump maximum pressure (5–15 bar), pre-infusion pressure (none to 5 bar) and time (0–15 s), and the unevenness of permeability σ (0–1.2); then press 'Wet again'. The square on the left is a wetting map of the puck's cross-section split into 20×20 columns, darkening from pale yellow to brown over time, with columns wet to the bottom shown dark brown. The chart beside it shows the wet share (orange) and pressure above the puck (purple dashed) over time. The table gives the time for the first column to wet through, the wet share at that moment, the time for half the columns and for all columns to wet through
```

## What this conclusion leaves out

- **The model values fit one machine and one coffee.** Foster and colleagues used a home machine with 10 g of coffee. Numbers will differ for café machines and 18 g pucks. The coarse grind was not fitted
- **Water does not flow sideways between columns.** In reality water would spread from wetter areas, making the front more even than this. The spread of permeability between columns (σ) is also an assumption
- **Swelling, dissolution and CO₂ are not included**
- **Accounts differ on how much of a shot wetting takes.** Foster and colleagues said it may take up to a third of a shot; Cameron and colleagues (2020) said it is a small part
- **Foster's times include a start delay (0.796 s)** and may differ from time measured from switching on the pump

## Summary

- Foster and colleagues (2025) imaged an espresso puck wetting with CT once a second. A fine grind barely wetted for the first 2 s and was fully wet by about 7 s, with a sharp, flat wetting front
- Rebuilding their model (pump curve, air trapped above the puck, Darcy flow) reproduced the 6.67 s to full wetting. Flow into the puck dropped to a fifth within a second or so of pooling, then rose again
- The headspace height changed the wetting time most (4.5–11.2 s for 3–20 mm). The pump's maximum pressure changed it by only a second or so
- With uneven permeability (σ 0.6), the first path opened at 3.8 s and the last took 19.5 s. When the first path opened, only 39% of the puck was wet
- In this model, pre-infusion only delayed wetting and did not even out the front. Any benefit would have to come through processes absent from the model, such as swelling or CO₂

## References

- Foster J, Lee W, Moroney KM, Prjamkov D, Salamon M, Smith A, Petrassem-de-Sousa J, Vynnycky M (2025). Dynamics of liquid infiltration into an espresso bed using time-resolved micro-computed tomography: insights from experiment and modeling. *Physics of Fluids* 37(1), 013383. [doi:10.1063/5.0245167](https://doi.org/10.1063/5.0245167)
- Mo C, Johnston R, Navarini L, Liverani F, Ellero M (2023). Exploring the link between coffee matrix microstructure and flow properties using combined X-ray microtomography and smoothed particle hydrodynamics simulations. *Scientific Reports* 13, 16374. [doi:10.1038/s41598-023-42380-y](https://doi.org/10.1038/s41598-023-42380-y)
- Smrke S, Wellinger M, Suzuki T, Balsiger F, Opitz SEW, Yeretzian C (2018). Time-resolved gravimetric method to assess degassing of roasted coffee. *Journal of Agricultural and Food Chemistry* 66(21), 5293–5300. [doi:10.1021/acs.jafc.7b03310](https://doi.org/10.1021/acs.jafc.7b03310)
- Cameron MI, Morisco D, Hofstetter D, Uman E, Wilkinson J, Kennedy ZC, Fontenot SA, Lee WT, Hendon CH, Foster JM (2020). Systematically improving espresso: insights from mathematical modeling and experiment. *Matter* 2, 631–648. [doi:10.1016/j.matt.2019.12.019](https://doi.org/10.1016/j.matt.2019.12.019)
- Corrochano BR (2017). *Advancing the engineering understanding of coffee extraction*. EngD thesis, University of Birmingham — CO₂ retained in ground coffee (4–12 mg per gram)

## Image credits

- Bottomless portafilter: massage-techniques, [Wikimedia Commons](https://commons.wikimedia.org/wiki/File:Pulling_a_triple_espresso_shot_with_a_naked_portafilter,_view_from_the_bottom.jpg), CC BY-SA 2.0
- All other charts, the cover and the tool: made by me