title: Why More Pressure Doesn't Mean More Flow
url: https://oosioo.com/en/p/%EC%95%95%EB%A0%A5%EC%9D%84-%EC%98%AC%EB%A0%A4%EB%8F%84-%EC%9C%A0%EB%9F%89%EC%9D%B4-%EB%8A%98%EC%A7%80-%EC%95%8A%EB%8A%94-%EC%9D%B4%EC%9C%A0
date: 2026-11-18T13:06:25+00:00
author: SYSOP
summary: Raising espresso pressure from 6 to 9 bar adds only 6% to the flow. Solving the poroelastic model Waszkiewicz et al. (2026) fitted to 60 café shots shows why: the pressure water loses squeezes the particles, compacting the puck near the screen, so at 9 bar the bottom 1 mm uses 36% of the pressure. Inertia reduces flow by less than 1% in a real shot. Includes a pressure–flow calculator.
---
# Why More Pressure Doesn't Mean More Flow

By Darcy's law, doubling the pressure should make water flow twice as fast. Yet the coffee industry has long known from experience that raising an espresso machine's pressure from 6 to 9 to 12 bar does not make shots correspondingly faster. In 2026 a study measured this quantitatively: as pressure rose, flow increased up to about 5 bar and then barely increased at all.

I solved that study's explanation numerically. 9 bar is a force that pushes the water and also presses the puck down onto the screen. As the squeezed bottom layer compacts, any extra pressure is spent getting through that thin layer. At 9 bar, the bottom 1 mm of the puck uses 36% of the whole pressure. Inertia, the other explanation sometimes offered, reduces flow by less than 1% in a real shot.

## Flow that does not rise with pressure

![Front of a stainless-steel espresso machine. On the right is a round pressure gauge with its needle near mid-scale; on the left a digital temperature display reads 94; a grinder stands beside it](/uploads/d7dd39ed275bc5fd.webp =600)
*A home espresso machine with a pressure gauge* · Photo: massage-techniques, Wikimedia Commons, CC BY-SA 2.0

Waszkiewicz and colleagues (2026) brewed 60 coffees on a café espresso machine, changing the pressure on the basket in 11 steps. They tamped 18.5 g of coffee in a 58 mm basket and ran each shot for more than 120 s, measuring the stable flow after almost all the soluble material had dissolved. Below 5 bar this flow was nearly proportional to pressure; above it, raising the pressure barely increased it.

Fitting the measurements to a poroelastic model gave two constants: a calibration flow Qc = 1.90 ± 0.15 g/s and a calibration pressure Pc = 12 ± 3 bar. The model's pressure–flow curve has almost the same shape whatever the coffee or porosity, so it can be written simply as:

**Q = Qc · [1 − (1 − P/Pc)⁴]**

![Long-time flow (g/s) against pressure (0–15 bar). The grey dashed line (Darcy's law, puck unchanged) rises straight, passing 3 g/s at 5 bar. The orange curve (poroelastic model, Pc 12 bar, Qc 1.90 g/s) follows the dashed line at first, then bends: 1.30 g/s at 3 bar, 1.78 g/s at 6 bar and 1.89 g/s at 9 bar, almost flat. Two faint orange lines for Pc 9 and 15 bar show the fit uncertainty](/uploads/67d1c39a8e6baa87.webp =760)

On this curve, flow is 1.30 g/s at 3 bar, 1.78 g/s at 6 bar and 1.89 g/s at 9 bar. Raising the pressure 50% from 6 to 9 bar adds only 6% to the flow. If the puck were not compressed and Darcy's law applied as is, 9 bar would give more than 7 g/s.

## The water squeezes the puck

Why? As water loses pressure passing through the puck, that force is handed to the particles. At the top surface the water holds all 9 bar and the particles are barely pressed. Further down the water pressure falls, and the force pushing the particles downward builds up by the same amount. The particles just above the screen carry all 9 bar. In soil and rock mechanics this is called Terzaghi's principle of effective stress.

Wet coffee particles deform and press into each other when squeezed. Waszkiewicz and colleagues treated this as simple elasticity: squeezing reduces the voids, and fewer voids reduce permeability according to the Kozeny–Carman equation. Then the puck gets denser toward the bottom, water loses more pressure where it is denser, and that pressure presses the particles further. This feedback caps the flow.

I solved the model numerically to look inside the puck, with a puck 13.6 mm thick, an unstressed porosity of 0.12, and Pc and Qc set to the values above.

![Three charts with height above the screen (0–13.6 mm) up, for applied pressures of 3, 6, 9 and 11 bar in different colours. On the left, 'Water pressure': at 3 bar it falls almost linearly with height, but at 9 and 11 bar it drops sharply in the bottom few millimetres. In the middle, 'Voids': all are 0.12 at the top surface and shrink toward the screen, reaching 0.093 at 3 bar, 0.064 at 6 bar, 0.033 at 9 bar and 0.011 at 11 bar at the bottom. On the right, 'Permeability' (log): falling from 1 at the top toward the screen, to below a thousandth at the bottom for 9 and 11 bar](/uploads/24f51aa50a25a5ad.webp =760)

At 3 bar, water pressure falls almost evenly with height. The bottom 1 mm uses 0.33 bar, 11% of the total. At 9 bar, the bottom 1 mm uses 3.25 bar, 36%, and the bottom 3 mm use 58%. Porosity just above the screen falls from 0.12 to 0.033, and permeability there is about a fiftieth of its unstressed value. Raise the pressure further and the bottom layer compacts more, so almost all of the extra pressure is spent in that layer.

In this model, the apparent permeability at 9 bar is 17–30% of the unstressed puck's (I varied the unstressed porosity from 0.05 to 0.3). In "Porous Media 101", permeability calculated from dry grounds was about a thousand times larger than a real shot's; compaction by pressure explains about a factor of three of that. The rest is already built into the unstressed permeability this model fits (about 1–2×10⁻¹⁴ m²), with swelling of wet particles and fines as candidates.

## Could it be inertia?

There is another explanation for flow that does not rise with pressure. As flow speeds up, inertia adds resistance when water has to turn around particles. This is called the Forchheimer effect. Mo and colleagues (2023) simulated water flowing through CT images of illy capsule pucks and found that as the pressure gradient rose from 50 to 400 bar/m, apparent permeability fell from 5.2 to 2.5×10⁻¹³ m². They attributed this to inertia, not deformation of the puck.

I estimated the size of inertia in a real shot. Using the Ergun equation's ratio of inertial to viscous resistance in a porous medium, for a flow of 36 g in 28 s at 9 bar, the ratio is 0.06% for 30 µm particles and still only 0.6% for 300 µm particles.

![Horizontal bar chart (log axis, reduction in flow, %). The orange bar 'compaction: drop in permeability at 9 bar' is 75% (error bar 70–83%). Three blue 'inertia' bars are 0.063% for 30 µm particles, 0.21% for 100 µm and 0.63% for 300 µm](/uploads/89ba15036f51a2f8.webp =760)

The two explanations differ by more than a hundredfold. Mo's simulations used the structure of dry capsule pucks, with a permeability about two hundred times that of a real shot, so water moves much faster at the same pressure gradient and inertia grows. Wadsworth and colleagues (2026) also concluded that espresso flow is laminar and within the range where Darcy's law holds (while noting it is close to the inertial regime). As the reason flow saturates in a real shot, compression of the puck is far more plausible.

## Change the pressure yourself

In the calculator below, change the pressure to see the long-time flow and the water pressure and porosity through the puck at that point. You can also change the calibration pressure Pc, calibration flow Qc and the unstressed porosity. The smaller Pc is, meaning the softer the puck, the lower the pressure at which flow saturates.

```map /embed/coffee-pressure-2026-en.html 16:9
Pressure and flow calculator. Sliders on the right set the applied pressure (0.5–15 bar), calibration pressure Pc (6–18 bar), calibration flow Qc (0.8–3 g/s) and unstressed porosity (0.05–0.4). The top-left chart shows flow against pressure (orange curve), the Darcy line if the puck were not compressed (dashed) and the current point. The bottom-left chart shows water pressure (blue) and porosity (purple dashed) through the puck from the screen to the top. The table gives flow, time to 36 g, flow if not compressed, porosity just above the screen and the share of pressure used by the bottom 1 mm
```

## What this conclusion leaves out

- **Only stable flow is covered.** Both the model and the measurements are of flow after more than 120 s, when almost all the solubles have dissolved. The first seconds of a real 25–30 s shot, while water soaks in and particles swell, behave differently
- **The puck is treated as a simple elastic body.** The elastic modulus of wet coffee grounds has never been measured; Pc stands in for it
- **The puck thickness (13.6 mm) and unstressed porosity are assumptions.** The shape of the flow curve barely depends on porosity, but the numbers in the profiles do
- **The inertia estimate uses the Ergun constants as they are.** They may differ for angular particles like coffee, though hardly enough to overturn a hundredfold difference
- **Machines differ.** Depending on the pump, pressure regulation and basket, the pressure actually on the basket can differ from the gauge reading

## Summary

- Waszkiewicz and colleagues (2026) brewed 60 coffees on a café machine and found that stable flow was proportional to pressure below 5 bar and barely rose above it. The fitted constants were Qc 1.90 g/s and Pc 12 bar
- The pressure water loses is handed to the particles. Particles nearer the screen are squeezed harder, their voids shrink, and water loses more pressure there
- Solving this model, at 9 bar the bottom 1 mm of the puck uses 36% of the pressure and porosity just above the screen falls from 0.12 to 0.033. Apparent permeability is 17–30% of the unstressed puck's
- Inertia (the Forchheimer effect) reduces flow by less than 1% in a real shot. The inertial effect seen in dry puck structures belongs to conditions with about two hundred times the permeability

## References

- Waszkiewicz R, Myck M, Białas Ł, Puciata-Mroczyńska M, Dzikowski M, Szymczak P, Lisicki M (2026). Under pressure: poroelastic regulation of flow in espresso brewing. *Physics of Fluids* 38(6), 063113. [doi:10.1063/5.0319611](https://doi.org/10.1063/5.0319611) · [arXiv:2512.21528](https://arxiv.org/abs/2512.21528)
- Mo C, Johnston R, Navarini L, Liverani F, Ellero M (2023). Exploring the link between coffee matrix microstructure and flow properties using combined X-ray microtomography and smoothed particle hydrodynamics simulations. *Scientific Reports* 13, 16374. [doi:10.1038/s41598-023-42380-y](https://doi.org/10.1038/s41598-023-42380-y)
- Wadsworth FB et al. (2026). A model for the permeability of coffee pucks validated using X-ray computed micro-tomography. *Royal Society Open Science* 13, 252031. [doi:10.1098/rsos.252031](https://doi.org/10.1098/rsos.252031)
- Ergun S (1952). Fluid flow through packed columns. *Chemical Engineering Progress* 48, 89–94 — bibliographic details only

## Image credits

- Espresso machine with a pressure gauge: massage-techniques, [Wikimedia Commons](https://commons.wikimedia.org/wiki/File:Lelit_Semiautomatic_Espresso_Machine_with_PID_and_Pressure_Gauge.jpg), CC BY-SA 2.0
- All other charts, the cover and the calculator: made by me